Anyone reccomend any tools for checking this ?
Im having some belt issues, that usually result in a shredded belt.
My crank pulley should be 100% and looks to run true. But I had to have my blower pulleys custom made, so I chose pulley dimensions.
By eye, it looks pretty good. But unless belt is extemely tight, it gets shredded after about 1st, 2nd, then 3rd gear, a lot more often than I can handle. Belt wrap isnt great, I'd guess at around 200-220 deg at best. But when very tight, belt seems to last. But it also caused me to wreck the blower bearings.
I also have slippage, despite being on a 10-rib 8.25/3.15 combo on YSi, again, unless its very tight. When tight, it works fine.
By tight, I cannot turn belt thru 90deg, and it plucks like a guitar. At 120lbft by Blownbys suggestion in the Vortech bracket, belt grips, but it feels damn tight.
At 80lbft, I get slippage above 7psi.
I tried moving tha idler closer to get more wrap. Belt shredded much easier.
Current belt is 63" long, Gates Micro-V driving the blower only. Blower is first item from the crank, with quite a long 19" of belt with no pulley contact.
I do have belt dust, but wouldnt say its excessive ???
How accurately must the pulleys be aligned ? My bracket does flex visibly when the belt is tensioned. Not a huge amount, but it is visible. I assume this too would effect alignment ?
Lots of questions...but I need this sorted. I want a system that grips all the time, without having to resort to tightening for racing, and slackening for the road. If I could get say 3000miles without even having to think about the belt, I'd be more than happy.
Bookmarks